Fluke 125 ScopeMeter 40MHz Industrial Scope meter Industrial oscilloscope

Fluke 125 ScopeMeter 40MHz Industrial Scope meter Industrial oscilloscope

Product Description

Product Description
Fluke 125, the full specifications of the Fluke 124 applies. On top, the Bus Health Test capability is included, as specified below. For further details on the general specification of the 125, refer to the 123/124 section

Specifications:

Bandwidth: 40 MHz


Sample Rate: 2.5 GS/s repetitive sampling
25 MS/s single shot sampling


Bus Health Test functions
Bus Health test: Verifies the electrical parameters of industrial bus systems using automatic measurement and analysis functions. Next to that, an Eyepattern mode is provided for visual inspection of signal quality.

Parameter classification: Default values:
• Well within limits = ‘ Good'
• Within certain percentage of the limit values = ‘ Weak'
• Beyond limit values = ‘ Bad'
Limits values, as a default, are based on industry standard for the selected bus type or may be set by the user.

Bus systems supported: • AS-I (EN50295, 166 kb/s);
• CAN-bus (ISO-11898, up to 1 MB/s);
• Interbus S (EIA-485, 500 kb/s);
• ControlNet (61158 type 2, 5MB/s);
• Modbus (EIA-232 up to 115 kb/s and EIA-485 up to 10 MB/s);
• Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s);
• Profibus DP (EIA-485 up to 10 MB/s);
• Profibus PA (61158 type 1, 31.25 kb/s);
• Ethernet 10Base2 (coaxial);
• Ethernet 10BaseT (UTP, 10 MB/s);
• RS-232 (EIA-232, up to 115 kb/s);
• RS-485 (EIA-485, up to 10 MB/s);
• User defined single wire or balanced system.

Modes: • Waveform Parameter analysis with automatic read-out and parameter validation (good / weak / bad); Test limits are based on industry standards or may be set by the user.
• Eyepattern display mode.

Measured parameters (where applicable): • Baud rate,
• Risetime,
• Fall time,
• High level,
• Low level,
• Bias voltage level,
• Signal amplitude,
• Distortion,
• Jitter.

Eyepattern display mode: Gives waveform display of bus signals with display persistence. Timebase and attenuator settings may be altered by the user.
Additional  Power  measurement  capabilities  (Fluke  125  only)
Measurement  types:
  Watt,
  VA,
  VAR,
  Power  Factor  (PF)
Power  configuration:
    Single  phase  or  balanced  three-phase  (delta-configuration)  mains  supply
Voltage  measurement
    Channel  A;   using  STL120,   voltage  probe  or  direct  input
Current  measurement
    Channel  B,   using  i400s  (included)  or  other  compatible  current  clamp
Current  Clamp  or  Shunt  sensitivity:
    0.1  /  1  /  10  /  100  /  1000  mV/A,   10  mV/mA  and  400  mV/A.
 
Harmonics  Mode  (Fluke  125  only)
 
    Converts  waveform  information  into  a  harmonics  display  (using  FFT  processing)  which  shows  the  relative  amplitudes 
of  the  1st  up  to  the  33rd  harmonic
Analyzed  waveform:
    Voltage  waveform(Ch. A),   Current  wavefrom  (Ch. B)  or  Power  (Ch. A  x  Ch. B),   automatically  generated.
Harmonics  Frequency  range:
    DC  up  to  33rd  harmonic  (for  fundamental  up  to  60  Hz);
    DC  up  to  24th  harmonic  (for  fundamental  up  to  400  Hz).
Display
    Bargraph  showing  1st  up  to  33rd  harmonic  and  DC;   amplitude  displayed  in  %  relative  to  fundamental
Measurements:
    Relative  amplitude  of  individual  harmonics;
    THD  in  %r  or  %f.